Title

Pharmacokinetics, clot strength and safety of a new fibrinogen concentrate: randomized comparison with active control in congenital fibrinogen deficiency

Publication Date

2018

Journal Title

J Thromb Haemost

Abstract

© 2017 The Authors. Journal of Thrombosis and Haemostasis published by Wiley Periodicals, Inc. on behalf of International Society on Thrombosis and Haemostasis. Essentials Congenital afibrinogenemia causes a potentially life-threatening bleeding and clotting tendency. Two human fibrinogen concentrates (HFCs) were compared in a randomized pharmacokinetic study. Bioequivalence was not shown for AUCnorm, which was significantly larger for the new HFC. Increases in clot strength were comparable, and no thromboses or deaths occurred in the study. Summary: Background Human fibrinogen concentrate (HFC) corrects fibrinogen deficiency in congenital a-/hypofibrinogenemia. Objectives To assess pharmacokinetics (PK), effects on thromboelastometry maximum clot firmness (MCF), and safety of a new double virus-inactivated/eliminated, highly purified HFC vs. active control. Patients/Methods In this multinational, randomized, phase II, open-label, crossover study in 22 congenital afibrinogenemia patients aged ≥ 12 years, 70 mg kg−1of new HFC (FIBRYGA, Octapharma AG) or control (Haemocomplettan®P/RiaSTAP™, CSL Behring GmbH) were administered, followed by crossover to the other concentrate. Fibrinogen activity, PK and MCF in plasma were assessed. Results The concentrates were not bioequivalent for the primary endpoint, AUCnorm(mean ratio, 1.196; 90% confidence interval [CI], 1.117, 1.281). Remaining PK parameters (Cmaxnorm, IVR, t1/2, MRT) reflected bioequivalence between concentrates, except for clearance (mean ratio, 0.836; 90% CI, 0.781, 0.895) and Vss(mean ratio, 0.886; 90% CI, 0.791, 0.994). Mean AUCnormwas significantly larger for the new HFC (1.62 ± 0.45 vs. 1.38 ± 0.47 h kg g L−1 mg−1, P = 0.0001) and mean clearance was significantly slower (0.665 ± 0.197 vs. 0.804 ± 0.255 mL h−1 kg−1, P = 0.0002). Mean MCF increased from 0 mm to 9.68 mm (new HFC) and 10.00 mm (control) 1-hour post-infusion (mean difference, −0.32 mm; 95% CI, −1.70, 1.07, n.s.). No deaths, thromboses, viral seroconversions or serious related adverse events occurred. Conclusions Bioequivalence was not demonstrated for AUCnorm, clearance and Vss. Larger AUCnormand slower clearance were observed for the new HFC. Remaining pharmacokinetic parameters reflected bioequivalence to control. Safety profiles and increases in clot strength were comparable between concentrates.

Volume Number

16

Issue Number

2

Pages

253 - 261

Document Type

Article

Status

Faculty

Facility

School of Medicine

Primary Department

General Pediatrics

PMID

29220876

DOI

10.1111/jth.13923

For the public and Northwell Health campuses

Share

COinS