Title

Surgeon performed ultrasound-guided fine-needle aspirates of the thyroid: 1067 biopsies and learning curve in a teaching center

Publication Date

2015

Journal Title

Head Neck

Abstract

BACKGROUND: Surgeon performed ultrasound-guided fine-needle aspirates (UG-FNAs) reduce delay in diagnosis and allow for surgeon surveillance. We present the first report on a learning curve and impact of head and neck surgical trainees on adequacy rates. METHODS: Thyroid UG-FNA biopsies from 2009 to 2013 were reviewed retrospectively. Specimen adequacy, cytologic diagnosis, and surgical pathology were used to calculate adequacy and accuracy. RESULTS: One thousand sixty-seven biopsies were examined in 723 individuals. The adequacy rate from adoption into practice improved from 71% to 78% to 85% over 300 cases. When UG-FNA was subsequently taught to trainees, adequacy rates varied among trainees (p < .037), and there were higher nondiagnostic rates earlier in training (p = .04). Adequacy was not related to size or palpability, but cystic lesions yielded more inadequate specimens (p < .001). CONCLUSION: Surgeon performed UG-FNA biopsy can be performed adequately in an outpatient setting. Adequacy rates reach acceptable levels after 300 cases, whereas trainee involvement impacts adequacy rates. (c) 2015 Wiley Periodicals, Inc. Head Neck, 2015.

Volume Number

38

Issue Number

Suppl 1

Pages

E1281-4

Document Type

Article

EPub Date

2015/09/01

Status

Faculty

Facility

School of Medicine

Primary Department

Otolaryngology

Additional Departments

Surgery

PMID

26316053

DOI

10.1002/hed.24212

For the public and Northwell Health campuses

Share

COinS