Failed Proximal Humerus Osteosynthesis Using Intramedullary Fibular Strut Allograft Conversion to Reverse Shoulder Arthroplasty

Publication Date

2019

Journal Title

Tech Hand Up Extrem Surg

Abstract

© 2019 Wolters Kluwer Health, Inc. All rights reserved. Comminuted proximal humerus fractures are more frequently being treated utilizing an intramedullary fibular strut allograft to assist with open reduction internal fixation. Although this technique has led to improved outcomes, avascular necrosis, rotator cuff failure, and/or prominent hardware may still occur necessitating conversion to reverse shoulder arthroplasty. The presence of an intramedullary strut allograft makes this conversion technically demanding and creates certain potential complications unique to this group. This manuscript details the conversion of a proximal humerus open reduction internal fixation with a fibular strut allograft to reverse shoulder arthroplasty including presurgical workup, surgical techniques, and pitfalls for undertaking this increasingly common scenario.

Document Type

Article

Status

Faculty

Facility

School of Medicine

Primary Department

Orthopedic Surgery

PMID

31436758

DOI

10.1097/BTH.0000000000000260

For the public and Northwell Health campuses

Share

COinS